The PSR-11-39-MD, also known as the R22D, is a high-performance galvanic oxygen sensor used in closed-circuit rebreathers (CCR) like the Dive Rite O2ptima.
Technical Specifications:
- Measurement Range: 0-100% oxygen
- Accuracy: ±2% of full scale
- Output Signal: 8.5 to 14 mV in air (20.9% O₂) at 25°C and 1 atm
- Response Time (T90): ≤ 6 seconds
- Temperature Compensation: Yes
- Operating Temperature: 0 to 45°C
- Humidity Range: 0–99% RH (non-condensing)
- Expected Shelf Life: ~42 months (sealed)
- Connector: 3-pin Molex
- Label/Model ID: R22D or PSR-11-39-MD
Key Features:
- Hydrophobic membrane to protect from moisture
- Temperature compensation for accuracy in variable conditions
- Conformal coating for durability in harsh environments
- Fast response time for accurate PPO₂ tracking while diving
Rebreather Compatibility:
- Compatible with many CCR models, including:
- Dive Rite O2ptima
- Poseidon Se7en & Discovery VI
- Hollis Prism 2 and Explorer MK2
- KISS Rebreathers
- Hammerhead
- Liberty
- SubGravity
- Not compatible with ISC Megalodon or Mares rEvo.
Usage Notes:
- Allow the sensor to stabilize before calibration after opening.
- Prolonged exposure to pure oxygen, heat, or physical shock may shorten sensor life.
- For safety, replace sensors every 12 months even if still functioning.